History data
Meaning of the columns:
pos
PV
TL
PVG
state
max. count
used_count
i
When a specific physical volume is queried (volume number specified in the query box) a
detailed overview is output:
The data for the selected PV is output in the title bar (see
This is followed by a list of the (valid) logical volumes stored on the PV.
282
Line number
Number of the physical volume
Tape Library: Name of the archive
Name of the physical volume group, usually starts at "CLNP".
status
The following values are possible for cleaning cartridges:
o___
("scratch") when the volume has just been added.
_r__
Read volume, has no more space for additional data. This is the normal
state of a cleaning cartridge.
f___
("faulty") when all the cleaning cycles have been used up.
Initial number of cleaning cycles
Number of cleaning cycles used
The PLM uses the cleaning cartridges as far as possible in such a way that one
cartridge is used up fully before the next one is started. However, if a number of
cleaning requests are to be carried out at the same time, the cartridges that are
available will also be used simultaneously.
Global Status
page
279).