Sxsc; Sxsd - Fujitsu Siemens Computers pmn User Manual

Centricstor v3.1d user guide
Table of Contents

Advertisement

Explanation of console messages
SXSB007
<PC> : fcpal<n> (sadm<m>): timeout on target <t> lun <l> CDB <some bytes>
ALERT
i
Meaning
An I/O operation has taken too long (minutes!), and as a result has been stopped and
started again.
Response
Notify maintenance staff.
9.2.18 SXSC... (Savecore: organize coredump)

SXSC001

<timestamp> syslog: savecore: dump has been saved in /var/crash
ALERT
Meaning
The previous SINIX session was terminated with a crash. A crash dump was taken which
was automatically saved in the /var/crash directory when the system was rebooted.
Response
Notify maintenance staff.
9.2.19 SXSD... (SCSI Disks: driver shd)

SXSD010

shd<k>t<ctl>: Hostadapter error
ALERT
Meaning
This message indicates a serious error in the communication with the RAID system.
Response
If this message is preceded by the message
xxx: response: error = 0x03, vendor = 0x1d, .... (the 0x1d is important)
it does not have to be analyzed further. In all other cases, notify maintenance staff.
SXSD013
shd<k>t<ctl>: TIMEOUT @ nnnnnnn
ALERT
See the
SXSD015
shd<k>t<ctl>:
"Drive Not Ready" (0x04) ascq 0x02
WARNING
See the
U41117-J-Z125-7-76
For more information, see the
page 538
and
section "Timeout on the MTC drives" on page
section "Failover at the RAID system" on page 541
cmd "Write or Read" @ blk <number> key "Not Ready" (0x02) asc
section "Failover at the RAID system" on page 541
section "Timeout on the RAID disk array" on
Message lines