Explanation of console messages
9.2.15 SXRD... (FibreCAT: RAID)
The table below shows the message numbers with the RAID systems which issue the
messages:
Message number

SXRD001

SXRD100 - SXRD104
SXRD002 - SXRD009
SXRD010
SXRD501, SXRD901
9.2.15.1

Messages of the monitoring daemon for the internal RAID

Messages during ongoing operation
SXRD001
NOTICE: raidd: 0:BBU - charging [xx] completed
SXRD001
NOTICE: raidd: 0:BBU - charging [xx] in progress
Meaning
These messages are normal when the BBU on controller 0 is in operation.
SXRD001
ALERT: raidd: 0:BBU - charging [xx] failed
SXRD001
ALERT: raidd: 0:BBU - pack not present
SXRD001
ALERT: raidd: 0:BBU - module not present
SXRD001
ALERT: raidd: 0:BBU - high temp
SXRD001
ALERT: raidd: 0:BBU - low voltage
SXRD001
ALERT: raidd: 0:BBU - cycles exceeded
Meaning
These messages indicate a hardware problem with the BBU on controller 0.
Response
Notify maintenance staff.
SXRD001
ALERT: raidd: 0:0:1 - disk state changed (Online -> Dead)
Meaning
The physical disk of controller 0, channel 0, target ID 1 has failed. All the associated logical
disks are without redundancy.
Response
Notify maintenance staff.