Fibrecat Cx500 And Cx3-20 Messages - Fujitsu Siemens Computers pmn User Manual

Centricstor v3.1d user guide
Table of Contents

Advertisement

Message lines
9.2.15.4

FibreCAT CX500 and CX3-20 messages

SXRD501
RAID: NOTICE <raid-id> Hard SCSI Error recovered (<#501>) c<ctrl>t<tgt>l<lun>
Where:
<raid-id>
c<ctrl>t<tgt>l<lun>
Meaning
Access via the specified path is possible again (positive message, cf. SXRD901).
SXRD901
RAID: ALERT <raid-id> Hard SCSI Error (<#901>) c<ctrl>t<tgt>l<lun>
Where:
<raid-id>
c<ctrl>t<tgt>l<lun>
Meaning
An error occurred while accessing the specified path. This can be the result of a defective
controller in theFibreCAT, an error in the FC switch or a defective cable.
Response
Notify maintenance staff.
490
ID of the FibreCAT (target # of the two RAID controllers)
Path via which the message was transferred
(ctrl = controller#, tgt = target#, lun = logical device)
ID of the FibreCAT (target # of the two RAID controllers)
Path via which the message was transferred
(ctrl = controller#, tgt = target#, lun = logical device)
Explanation of console messages