Message lines
9.2.14 SXPS... (PLS: Physical Library Server)
For the messages SXPS000 to SXPS008 of the robot software, only error numbers
#4000 - #4008 are described because these error messages are dependent on the robot.
The various error messages for robot types supported by at the current time are no longer
individually listed.

SXPS000

PLS(#4000) ERROR: 'vsn': <robot error message>
i
Meaning
The volume 'vsn' could not be found.
Response
Notify maintenance staff.
SXPS001
PLS(#4001) ERROR: `PDS-name`: <robot error message>
Meaning
The robot software does not know the LibDevName of the `PDS-name`.
Response
If the LibDevName of the `PDS-name` has been entered incorrectly, correct this in the
configuration (in SCSI robots the LibDevName is a number between 0 and the number of
drives minus 1). Or if the drive has not been released for the CentricStor system in the robot
software, release the drive on the robot control processor for the CentricStor system.
SXPS005
PLS(#4005) ERROR: 'PDS-name': <robot error message>
Meaning
The PDS <PDS-name> has not ejected a physical volume in a way that permits the robot
to take hold of it.
Response
Notify maintenance staff.
482
This message may also be issued if 'vsn' is jammed in a drive.
Explanation of console messages
U41117-J-Z125-7-76