Function bar
Buttons and entry fields
i
"NEW" button:
Adds a new LVG.
When you click on "NEW" the entry field for the name is opened. The button for the LV
type and the DELETE button appear. The button "NEW" is not offered if the maximum
number of LVGs (= 512) has been reached. After you have entered a name in the entry
field (and click "Enter" or any button) a line containing the newly entered name appears
in the list.
When the groups have been established the assignments of logical to physical disks
must be specified in a further step. This is done using operating functions of the PLM
while CentricStor is running (see
Volume Groups" on page
174
In the case of LVGs already distributed with "Distribute and Activate", the "To Be
Deleted" button is offered (as in the form above), in the case of newly entered LVGs
the "DELETE" button.
The "BASE" LVG is always present and cannot be deleted. The transfer LVG with
the name TR-LVG is also always present, but not shown in this menu.
section "Physical Volume Operations » Link/Unlink
221).