Fibrecat Cx500 And Cx3-20 Messages - Fujitsu Siemens Computers pmn User Manual

Centricstor v3.1d user guide
Table of Contents

Advertisement

Explanation of console messages
Response
In the event of a message with the error weight ALERT: Notify maintenance staff.
Example
SXRD003 s80d: RAID: ALERT: #212215 Enclosure 3, Power Supply 2 Critical
Connection between status and error weighting:
OK
Warning
Not Available
Unknown
Critical
Not Installed
Messages with the error weighting ALERT trigger a teleservice call. For the S80 this
applies to all faulty components with the status "Critical" or "Not Installed" (faulty hard
disks have the status "Not Installed").
A hardware fault can result in several different messages.
SXRD009
s80d: RAID:
Meaning
When the monitoring daemon starts (for example on reboot), information is read from the
connected FibreCAT S80 and the number of RAID controllers found per S80 is displayed
on the console.
The terms used here have the following meanings:
raid#
ccnt#
9.2.15.3

FibreCAT CX500 and CX3-20 messages

SXRD010
RAID: ALERT <raid-id> Raid<raid#>: not all HBAs of <isp-name> registered
Where:
<raid-id>
<raid#>
<isp-name>
Meaning
One or both HBAs of the specified ISP are not registered in the FibreCAT named.
Response
Notify maintenance staff.
U41117-J-Z125-7-76
NOTICE
WARNING
ERROR
ERROR
ALERT
ALERT
NOTICE:
Raid<raid#>: <ccnt> Controller OK
Number of the RAID system (1 – 8)
Number of the Controller (1 or 2)
ID of the FibreCAT (target# of the two RAID controllers)
Sequence RAID# (1 - 8)
Name of the ISP concerned
Message lines