Fujitsu Siemens Computers pmn User Manual page 518

Centricstor v3.1d user guide
Table of Contents

Advertisement

Message lines
SXVL006
VLM(# 6): ERROR: volume ??? set to 'Faulty' (???)
Meaning
This error can have a number of different causes. It is usually caused by problems
accessing the DTV filesystem. Further details can be found in the logging information.
Response
The logical volume can be reset using the XTCC function "Reset Logical Volume". However,
you should first check the cause as it may then be necessary to check the data on the
volume.
SXVL007
VLM(# 7): ERROR: Mount: <ldxx> on <icpyy> not reachable: <errormsg> (<errno>)
SXVL007
VLM(# 8): ERROR: Unload: <ldxx> on <icpyy> not reachable: <errormsg> (<errno>)
Meaning
The VLM cannot access the logical drive <ldxx>.
Response
Notify maintenance staff.
SXVL009
VLM(# 9): ALERT: no database file found, aborted, see log for details
Meaning
The VLM has not found a data maintenance file but, instead, a backup data maintenance
system. It is possible that the file system containing the data maintenance system is not
mounted.
Response
Notify maintenance staff.
SXVL010
VLM(#10): WARNING: too many open files in cache ???, mount of volume ??? queued
Meaning
The mount job for a logical volume has been queued because no more files can be opened
in the cache filesystem. This error may occur, for example, if the configuration is incorrect:
maximum number of files that can be opened in the TVC is too small.
Response
In unfavorable instances, this behavior may be normal, for example:
The mount jobs are distributed unequally to the individual caches.
The reorganization of physical tapes requires too many restore jobs.
SXVL011
VLM(#11): ERROR: Mount: mount server on <icpyy> not reachable: <errmsg> (errno)
SXVL012
VLM(#12): ERROR: Unload: mount server on <icpyy> not reachable: <errmsg> (errno)
Meaning
The VLM cannot access the mount server on the ICP <icpyy>.
Response
Notify maintenance staff.
518
Explanation of console messages
U41117-J-Z125-7-76

Advertisement

Table of Contents
loading

This manual is also suitable for:

Centricstor v3.1d

Table of Contents