Failure Of Raid Systems - Fujitsu Siemens Computers pmn User Manual

Centricstor v3.1d user guide
Table of Contents

Advertisement

Message complexes

9.3.3 Failure of RAID systems

SXVD001
vdrv<n> (FAILOVER): switch 0:40->1:41
SXVD001
vdrv<n> (FAILOVER): switch 1:41->0:40
SXVD002
vdrv<n> (FAILOVER): Error exit 0130002A E54EC000
Meaning
Both RAID controllers have failed. A failover (1st line) and switchback (2nd line) have been
performed but both without success; the RAID disk array with the next highest minor
number can no longer be accessed.
Example for vdrv3
The error message is:
vdrv3 (FAILOVER): Error exit 0130002A E54EC000
The directory of the vdrives has the following contents:
$ ls -l /dev/vdrv
total 0
brw-------
crw-------
brw-------
crw-------
brw-------
crw-------
The minor numbers here are 13, 26 and 39. The error was reported by vdrv3.
The next highest device is always decisive. Therefore the RAID disk array involved is
raid1.st1.fo.c (minor number 13), i.e. the first RAID disk array.
Only an error which occurs exactly on a minor number (i.e. here on vdrv13) is forwarded. If
required, errors on other subordinate devices will be corrected elsewhere by means of con-
figuring or restarting the IO.
Response
Notify maintenance staff.
540
1 root
other
1 root
other
1 root
other
1 root
other
1 root
other
1 root
other
Explanation of console messages
76, 13 May 15 15:44 raid1.st1.fo.b
76, 13 May 15 15:44 raid1.st1.fo.c
76, 26 May 15 15:44 raid1.st2.fo.b
76, 26 May 15 15:44 raid1.st2.fo.c
76, 39 May 15 15:47 raid2.st1.fo.b
76, 39 May 15 15:47 raid2.st1.fo.c
U41117-J-Z125-7-76