Error Conditions Indicated On The Display - Fujitsu Siemens Computers pmn User Manual

Centricstor v3.1d user guide
Table of Contents

Advertisement

Virtual 3490 drives
The display can contain one of the following messages:
Display 0
CU READY
CU ONL
EMU STOP
When a logical volume is loaded, the third line specifies which cache contains the
associated data.
8.10.1.1

Error conditions indicated on the display

Display 1
EMU STOP ERR #001
EMU STOP ERR #002
EMU STOP ERR #003
EMU STOP ERR #004
EMU STOP ERR #005
EMU STOP ERR #006
EMU STOP ERR #011
EMU STOP ERR #013
EMU STOP ERR #022
EMU STOP ERR #030
EMU STOP ERR #031
EMU STOP ERR #032
EMU STOP ERR #045
EMU STOP ERR #09
EMU STOP ERR #100
392
Display 1
--
--
NORMAL
Display 2
Meaning
BAD_IAT (address conflict between the emulation and the EXA
driver)
pcib open failed (no connection to the channel)
Index already exists (overlap in the kernel buffer address)
SIGSET for pcib
Device type not supported
Endless loop child (hard software error)
SIGBUS,-FPE,-SEGV (code overwritten)
Library init wrong
REG_EV (channel driver closed the connection to the
emulation)
VT_LS open error (initialization error)
VT_LS mount error
VT_LS Library Manager error
KBUF inconsistency (buffer inconsistency between the channel
and the emulation)
Test stop (trap)
PROCLOCK == ERR
Description
CU ready but path not yet connected.
CU ready, path connected.
Emulation stopped: normal end.