SIA / IFP-75 Panels PI Modifier Reporting:

Event Description
System-based Wireless Gateway
Trouble - restore
Wireless Gateway Trouble
Wireless Gateway Trouble restore
11.2 SIA / IFP-75 Panels PI Modifier Reporting:
Events are sent to the Central Station as a variable length string:
The Event Format is:
EEZZZZ
Where the Event Format is defined as follows:
Code
Event Code Description
EE
Event Code (2 characters)
ZZZZ
Event parameter (up to four digits – not zero filled)
1.
The Account Number is sent using an Account block that is separate from the Event block.
2.
Multiple events can be sent within a single Event block. Events are separated by a "/" character.
3.
The Event parameter can be a zone, point or module number.
4.
When Reporting-by-Point is enabled, the communicator uses a "pi" event to supersede the actual point event to report the module to
which the point is linked.
5.
The Panel ID is not sent in the SIA Event Parameters.
For Example see Table 11.3:
Event
Fire Alarm-Zone
Fire Alarm-Zone
Fire Alarm-Point
Fire Alarm-Point
Expander Trouble
Auto Test
Battery Trouble-Panel 32
Battery Trouble-Expander 18
SLC Loop Shorted
Program Begin Panel ID=32
Program Begin Panel ID= 22
AC Power Loss - Panel 22
Fire Trouble
Fire Trouble
Fire Trouble-Nac
Fire Trouble-Nac
IFP-75/IFP-75HV Installation/Operation Manual — P/N LS10147-001SK-E:D 06/25/2021
SIA Reporting Format
SIA pi Modifier
Module ID
SIA
Parameter
# (If Any)
Event
Codes
pi Exp. ID UJ
Point #
pi Exp. ID UT
Point #
pi Exp. ID UJ
Point #
Table 11.2 Reporting Formats Table (Continued)
Report Zone/ Point Panel ID Module Zone ZZZZ Point ZZZZ
Zone
n/a
Zone
n/a
Point
n/a
Point
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Point
n/a
Zone
n/a
Point
n/a
Zone
n/a
Table 11.3 :SIA- IFP-75 Panels - PI Modifier Reporting Examples
SIA
Fixed Length
Qualifier
Format NN - panel
ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
UJNNXXPPPP
3
UTNNXXPPPP
1
UJNNXXPPPP
3
n/a97
15
n/a
n/a
05
n/a
01
n/a
123
33
n/a
203
11
n/a
n/a
n/a
n/a
n/a
98
n/a
n/a
18
n/a
n/a
44
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
98
n/a
n/a
97
n/a
200
97
01
n/a
98
n/a
Nac Circuit
7
98
n/a
Nac Circuit
7
Reporting
Contact ID Reporting Format
Event
Group #
Contact #
Code
373
Exp. ID
Point #
373
Exp. ID
Point #
373
Exp. ID
Point #
Fields Sent
SIA Event Data
EE-ZZ
FA15
EE-Z
FA5
EE-ZZ /EE-ZZZ
pi01/FA123
EE-ZZ /EE-ZZZ
pi11/FA203
EE-ZZ
ET11
EE-Z
RP0
EE-ZZ
YT98
EE-ZZ
YT18
EE-ZZ
ET44
EE-Z
LB0
EE-Z
LB0
EE-Z
AT0
EE-ZZ /EE-ZZZ
pi97/FT200
EE-Z
FT1
EE-ZZ /EE-Z
pi98/FT7
Z=Pt. #
EE-ZZZ
FT400
ZZZ=OPG#
125