Honeywell IFP-75 Installation & Operation Manual page 120

Addressable fire alarm control panel
Hide thumbs Also See for IFP-75:
Table of Contents

Advertisement

Reporting
Event Description
Manual pull switch trouble
Manual pull switch trouble restore
Notification output trouble
Notification output trouble restore
Positive Alarm Sequence acknowledge
switch trouble
Positive Alarm Sequence acknowledge
switch trouble restore
SLC LED Module trouble
SLC LED Module trouble restore
Status Point Types Trouble
Status Point Types Trouble Restore
Supervisory Detector Alarm
Supervisory Detector Alarm Restore
Supervisory/Tamper Alarm
Supervisory/Tamper alarm condition re-
store
Supervisory/Tamper switch trouble
Supervisory/Tamper switch
trouble restore
System-based AUX1 switch alarm
System-based AUX1 switch alarm
restore
System-based AUX1 switch trouble
System-based AUX1 switch trouble
restore
System-based AUX2 switch alarm
System-based AUX2 switch alarm
restore
System-based AUX2 switch trouble
System-based AUX2 switch trouble re-
store
Voice Aux ECS 1 Alarm
Voice Aux ECS 1 Alarm Restore
Voice Aux ECS 2 Alarm
Voice Aux ECS 2 Alarm Restore
Voice Aux ECS 3 Alarm
Voice Aux ECS 3 Alarm Restore
Voice Aux ECS 4 Alarm
Voice Aux ECS 4 Alarm Restore
Water flow switch alarm
Water flow switch alarm Restore
Water flow switch trouble
Water flow switch trouble Restore
Zone-based AUX1 switch alarm
Zone-based AUX1 switch alarm restore
120
SIA Reporting Format
SIA pi Modifier
Module ID
SIA
Parameter
# (If Any)
Event
Codes
FT
Zone #
FJ
Zone #
FT
Group # + 1000
FJ
Group # + 1000
FT
Zone #
FJ
Zone #
ET
0000
ER
0000
UT
0
UJ
0
FS
Zone #
FR
Zone #
FS
Zone #
FR
Zone #
FT
Zone #
FJ
Zone #
UA
1000
UH
1000
UT
1000
UJ
1000
UA
2000
UH
2000
UT
2000
UJ
2000
UA
3
UH
3
UA
4
UH
4
UA
5
UH
5
UA
6
UH
6
SA
Zone #
SH
Zone #
ST
Zone #
SJ
Zone #
UA
Zone # + 1000
UH
Zone # + 1000
Table 11.2 Reporting Formats Table (Continued)
IFP-75/IFP-75HV Installation/Operation Manual — P/N LS10147-001SK-E:D 06/25/2021
Receivers Compatible with the Control Panel
Contact ID Reporting Format
SIA
Fixed Length
Qualifier
Format NN - panel
ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
FTNN000ZZZ
1
FJNN000ZZZ
3
FTNN001GGG
1
FJNN001GGG
3
FTNN000ZZZ
1
FJNN000ZZZ
3
ETNN000000
1
ERNN000000
3
UTNN000000
1
UJNN000000
3
FSNN000ZZZ
1
FRNN000ZZZ
3
FSNN000ZZZ
1
FRNN000ZZZ
3
FTNN000ZZZ
1
FJNN000ZZZ
3
UANN001000
1
UHNN001000
3
UTNN001000
1
UJNN001000
3
UANN002000
1
UHNN002000
3
UTNN002000
1
UJNN002000
3
UANN003000
1
UHNN003000
3
UANN004000
1
UHNN004000
3
UANN005000
1
UHNN005000
3
UANN006000
1
UHNN006000
3
SANN000ZZZ
1
SHNN000ZZZ
3
STNN000ZZZ
1
SJNN000ZZZ
3
UANN001ZZZ
1
UHNN001ZZZ
3
Event
Group #
Contact #
Code
373
00
Zone #
373
00
Zone #
320
00
Group #
320
00
Group #
373
00
Zone #
373
00
Zone #
333
00
000
333
00
000
379
00
000
379
00
000
200
00
Zone #
200
00
Zone #
200
00
Zone #
200
00
Zone #
373
00
Zone #
373
00
Zone #
140
01
000
140
01
000
373
01
000
373
01
000
140
02
000
140
02
000
373
02
000
373
02
000
171
00
000
171
00
000
172
00
000
172
00
000
173
00
000
173
00
000
174
00
000
174
00
000
113
00
Zone #
113
00
Zone #
373
00
Zone #
373
00
Zone #
140
01
Zone #
140
01
Zone #

Advertisement

Table of Contents
loading

This manual is also suitable for:

Farenhyt seriesIfp-75hv

Table of Contents