NETGEAR ProSAFE WC7500 User Manual page 370

Wireless controller
Hide thumbs Also See for ProSAFE WC7500:
Table of Contents

Advertisement

5.
Configure the settings as described in the following table.
Setting
Enable Console Logs
Server IP Address
Server Port Number
Server / L3 Switch MAC
Log Level
6.
In the table with access points, select one or more check boxes for access points for which
you want to collect debug logs.
You can select only access point that are in the Connected state. The table can display
WNDAP660, WAC720, WAC730, and WAC740 access points only.
7.
Click the Apply button.
Your settings are saved. The selected access points start generating and sending debug
logs over the network to the syslog or UDP server. (If a device is connected to the
console port of an access point, the access point also starts sending debug logs over the
console port.)
ProSAFE Wireless Controller
Description
Enable the console log settings by selecting the Enable Console Logs check
box.
By default, the console log settings are disabled.
Enter the IP address of the syslog server or UDP server.
Note:
If you use a syslog server on the network, the number of the logs that are
sent to the syslog server might increase considerably.
Enter the port number of the syslog server or UDP server.
The default port number is the syslog server port 514.
Enter the MAC address of the UDP server or Layer 3 gateway behind which the
UDP server is located:
If you use a UDP server, enter the MAC address of the UDP server. This
MAC address is required to enable the access point to send messages to
the UDP server.
If the UDP server is in another subnet (that is, the UDP server is located
behind a Layer 3 gateway), enter the MAC address of the gateway instead
of the MAC address of the UDP server.
From the Log Level menu, select one of the following levels:
EMERGENCY (1). Emergency messages. Sent when the system is
unstable.
ALERT (2). Alert messages. Sent when action must be taken immediately.
CRITICAL (3). Critical messages. Sent when a critical condition occurs.
ERROR (4). Error messages. Sent when an error condition occurs.
WARNING (5). Warning messages. Sent when a warning condition occurs.
NOTICE (6). Notification messages. Sent when a normal but significant
condition occurs.
INFORMATION (7). Informational messages.
DEBUG (8). Debug messages.
Note:
If you select EMERGENCY (1), only emergency messages are sent. For
each lower level, the messages of the levels that are higher than the selected
level are also sent. For example, if you select CRITICAL (3), critical messages,
alert messages, and emergency messages are sent. If you select DEBUG (8),
all messages from emergency messages to debug messages are sent.
Selecting DEBUG (8) generates a very large number of messages.
Troubleshooting and Diagnostics
370

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prosafe wc7600v2Prosafe wc7600Prosafe wc9500

Table of Contents