OC (Function ID: 440001)
Setting items
OC1-a
OC1-c
OC1-kr
OC1-b
Output
OC1-2fBlk
OC1-VTFBlk
OC1-OPMD
OC1-UseFor
OC1-ARCBlk
OC2
OC2-Dir
OC2-Angle
OC2-Timer
DT
OC2
OC2-DPR
TOC2
IEC
OC2
OC2-DPR
OC2-TMS-IEC
TOC2R
UK
OC2
OC2-DPR
OC2-TMS-UK
TOC2R
IEEE
OC2
OC2-DPR
OC2-TMS-
IEEE
OC2-Rtimer
TOC2R
OC2-RTMS-
IEEE
US
OC2
OC2-DPR
OC2-TMS-US
OC2-Rtimer
TOC2R
OC2-RTMS-US
ORG
OC2
OC2-DPR
OC2-TMS-ORG
OC2-Rtimer
Range
Unit
1A rating
5A rating
0.00000 - 10.00000
- OC1 user original curve coefficient
0.00000 - 10.00000
- OC1 user original curve coefficient
0.00000 - 500.00000
- OC1 user original curve coefficient
0.00000 - 10.00000
- OC1 user original curve coefficient
Non / Block-3P /
- OC1 operation block by 2f-detection
Block-PerP
Non / Block
- OC1 operation block by VTF
3POR / 2OUTOF3
- OC1 operation mode
Trip / Alarm
- OC1 used for trip or alarm
Non / Block
- Autoreclose block by OC1
NonDir / Forward /
- OC2 directional characteristic
Reverse
0 - 180
deg OC2 directional characteristic angle
DT / IEC-NI / IEC-VI /
IEC-EI / UK-LTI /
IEEE-MI / IEEE-VI /
- OC2 delay type
IEEE-EI / US-CO2 /
US-CO8 / Original
0.02 -
0.10 -
A OC2 threshold (in DT mode)
50.00
250.00
10 - 100
% OC2 drop-out/pick-up ratio
0.00 - 300.00
s OC2 operating delay time (in DT mode)
0.02 -
0.10 -
A OC2 threshold (in IDMT mode)
5.00
25.00
10 - 100
% OC2 drop-out/pick-up ratio
0.010 - 50.000
- OC2 time multiplier of IEC inverse curve
0.00 - 300.00
s OC2 definite time reset delay
0.02 -
0.10 -
A OC2 threshold (in IDMT mode)
5.00
25.00
10 - 100
% OC2 drop-out/pick-up ratio
0.010 - 50.000
- OC2 time multiplier of UK inverse curve
0.00 - 300.00
s OC2 definite time reset delay
0.02 -
0.10 -
A OC2 threshold (in IDMT mode)
5.00
25.00
10 - 100
% OC2 drop-out/pick-up ratio
0.010 - 50.000
- OC2 time multiplier of IEEE inverse curve
DEF / DEP
- OC2 reset delay type of IEEE
0.00 - 300.00
s OC2 definite time reset delay
OC2 dependent reset time multiplier of IEEE
0.010 - 50.000
-
inverse curve
0.02 -
0.10 -
A OC2 threshold (in IDMT mode)
5.00
25.00
10 - 100
% OC2 drop-out/pick-up ratio
0.010 - 50.000
- OC2 time multiplier of US inverse curve
DEF / DEP
- OC2 reset delay type of US
0.00 - 300.00
s OC2 definite time reset delay
OC2 dependent reset time multiplier of US
0.010 - 50.000
-
inverse curve
0.02 -
0.10 -
A OC2 threshold (in IDMT mode)
5.00
25.00
10 - 100
% OC2 drop-out/pick-up ratio
0.010 - 50.000
- OC2 time multiplier of ORG inverse curve
DEF / DEP
- OC2 reset delay type of US
- 168 -
6F2S1915 (0.46)
Contents
GRZ200 (Soft 031 & 032)
Default
Note
1A
5A
0.00000
0.00000
0.00000
0.00000
Non
Non
3POR
Trip
Block
NonDir
45
DT
1.00
5.00
100
1.00
1.00
5.00
100
1.000
0.00
1.00
5.00
100
1.000
0.00
1.00
5.00
100
1.000
DEF
0.00
1.000
1.00
5.00
100
1.000
DEF
0.00
1.000
1.00
5.00
100
1.000
DEF