Channel menu
5.6 Example: Settings for 1:N
Example netnames.ini
;******************************************************************
;
;
; This is an example of a netnames.ini for 1:N NCU-switching in
; a configuration of 3 NCU and a PCU50.
;*******************************************************************
[own]
owner = HMI
;***************************
; ChanMenu
;***************************
[chan HMI]
ShowChanMenu = true
;*******************************************************************
;Channel-groups
;Correlation from channel-group to horizontal softkeys
; -> see config.ini of the TCU
;The section [T2M2N] can also be created in the netnames.ini file
;instead of config.ini file. This configuration applies to all TCU,
;which are not configured by their config.ini.
;*******************************************************************
[T2M2N]
SK1 = CH_GRP_1
SK2 = CH_GRP_2
[CH_GRP_1]
Text = 1. NCU
Member1.Target = 192.168.214.241.192.168.214.1.#1
Member1.Text = NCU1%nKanal 1
Member2.Target = 192.168.214.241.192.168.214.1.#2
Member2.Text = NCU1%nKanal 2
[CH_GRP_2]
Text = 2. NCU
Member1.Target = 192.168.214.241.192.168.214.2.#1
Member1.Text = NCU2%nKanal 1
Member2.Target = 192.168.214.241.192.168.214.2.#2
Member2.Text = NCU2%nKanal 2
Note
For switching over an MCP with the operating software, the PLC block FB9 must not be used
(FB9 must not be active). If necessary, the MCP must be switched over in the PLC user
program.
46
netnames.ini
- EXAMPLE -
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
SINUMERIK Operate (IM9)