Siemens SINUMERIK 840D sl Commissioning Manual page 659

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Description
Properties are assigned to softkeys during definition of the softkey menu.
Programming
Syntax:
Description:
Parameters:
Syntax:
Description:
Parameters:
Note
Enter %n in the softkey text to create a line break.
A maximum of 2 lines with 9 characters each are available.
SINUMERIK Integrate Run MyScreens (BE2)
Programming Manual, 03/2013, 6FC5397-1DP40-3BA1
(Identifier)
//S
;Start identifier of softkey menu
...
//END
;End identifier of softkey menu
Defines softkey menu
Identifier
Name of softkey menu
Text or image file name
(Text[, Access level][, Status])
SK =
Define softkey
SK
Softkey, e.g. HS1 to HS8, VS1 to VS8
Text
Enter text
Display file name
"\\my_pic.png"
or via separate text file $85199, e.g. with the following
text in the (language-specific) text file: 85100 0 0
"\\my_pic.png".
The size of image which can be displayed on a softkey
depends on the OP used:
OP 08:
OP 010:
OP 012:
OP 015:
OP 019:
Access level
ac0 to ac7 (ac7: default)
Status
se1: visible (default)
se2: disabled (gray text)
se3: displayed (last softkey used)
4.2 Defining softkey menus
640 x 480 mm → 25 x 25 pixels
640 x 480 mm → 25 x 25 pixels
800 X 600 mm → 30 x 30 pixels
1024 X 768 mm → 40 x 40 pixels
1280 x 1024 mm → 72 x 72 pixels
Dialogs
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents