Backing Up Setup Data - Siemens SINUMERIK 840D sl Commissioning Manual

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Parameter
Archive format
RS-232-C settings (details)
Interface
Parity
Stop bits
Data bits
XON (hex)
XOFF (hex)
End of data transfer (hex)
Time monitoring (sec)
15.8

Backing up setup data

Setting for "Backup setup data"
The "Backup setup data" function should only be used if MD11280 $MN_WPD_INI_MODE is
set to 1 (default setting). Otherwise, when the NC is started for the first time after selecting
the part program, a file with the same name with the ".ini" extension would be automatically
executed.
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
Meaning
Punched tape
Binary format (PC format)
COM1
COM2 only relevant for SINUMERIK Operate on PC
Parity bits are used for error detection: The parity bits are added to the
coded characters to make the number of positions set to "1" an uneven
number (uneven parity) or to an even number (even parity).
None (default setting)
Odd
Even
Number of stop bits for asynchronous data transfer.
1 (default setting)
2
Number of data bits for asynchronous data transfer.
5 bits
...
8 bits (default setting))
Only for punched tape format
Only for punched tape format
Only for punched tape format
Stop with end of data transfer character
The default setting for the end of data transfer character is (HEX) 1A.
Time monitoring
For data transfer problems or at the end of data transfer (without end
of data transfer character) data transfer is interrupted after the
specified number of seconds.
The time monitoring is controlled by a time generator (clock) that is
started with the first character and is reset with each transferred
character. The time monitoring can be set (seconds).
Data backup
15.8 Backing up setup data
289