Procedure
21.2.7

Displaying cam signals

The signals of the cam SGA are displayed in the "Cam SGA" window.
Cam synchronization is executed between NCK and PLC at the cam SGA.
Procedure
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
1.
Select the "Diagnostics" operating area.
2.
Press the menu forward key and the "Safety" softkey.
3.
Press the "SI I/O" softkey.
The "SI I/O" window is opened and the status of the signals is
displayed.
Press the "Fail-safe modules" softkey to display the status of the fail-
safe modules and their PROFIsafe address.
4.
Press the "Details" softkey to display further information on this fail-safe
module.
1.
Select the "Diagnostics" operating area.
2.
Press the "Menu forward" key and then the "Safety" softkey.
3.
Press the "Output cam SGA" softkey.
The "Cam SGA" window opens.