Siemens SINUMERIK 840D sl Commissioning Manual page 845

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

"all", "system" and "network" are special values for the subsystem:
● On the other hand, "sc restart system" initiates a system restart (reboot)
● "network" can only be specified in conjunction with "restart". "sc restart network"
Examples
# stop all subsystems:
$ sc stop all
# only stop HMI:
$ sc stop hmi
# start HMI and NCK:
$ sc start hmi nck
# start all subsystems except NCK
$ sc start ! nck
2.5.13
Restore
Description
Syntax:
Alternative names:
Authorization level:
A backup created using "sc save" can be restored to the controller using "sc restore".
Mode of operation
As for "sc save", a restore is only possible from the service system or if subsystems are
stopped. If "sc restore" reports an error, for example that the restore will cause running
subsystems to crash, you can use the option "-force" to force the operation – just as for "sc
save".
Normally, "sc restore" deletes the whole target area before the backup is restored (complete
CompactFlash card for full backup, /user in user data backups). This means that no files not
included in the backup are subsequently available.
NCU operating system (IM7)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
"all" stops and starts all available subsystems.
reinitializes the network, e.g. after settings have been changed in basesys.ini.
sc restore [-full|-addon|-addon+|-oem|-oem+|-user]
[-force] [-nodelete] [-update] [-restart] FILENAME
---
user
Configuring the system
2.5 Description of the actions
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents