Network Settings - Siemens SINUMERIK 840D sl Commissioning Manual

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Data backup

15.9 Network settings

Machine data:
MD11280 $MN_WPD_INI_MODE
Processing mode of ini files in the workpiece directory
15.9
Network settings
Activate
By default, the network settings cannot be backed up. The archiving of the network settings
must be enabled:
1. Copy the "slpmconfig.ini" file from the /siemens/sinumerik/hmi/template/cfg directory.
2. Store the file in the /oem/sinumerik/hmi/cfg or /user/sinumerik/hmi/cfg directory.
3. Open the file and enter the following for [SeriesSetup]:
SupportNetworkSettings=true
4. Restart SINUMERIK Operate.
Note
This setting also affects the creation of a complete standard archive using Ctrl+Alt+S or
Ctrl+Alt+C.
290
= 1 When the NC is started for the first time, after the workpiece selection, ini files with the name
of the selected part program and the following extensions are executed:
CEC
Sag compensation (Cross Error Compensation)
GUD
User data (Global User Data)
PRO
Protection zones
RPA
R parameters
SEA
Value assignments (Setting Data Active)
TMA
Magazine data (Tool Magazine Active)
TOA
Tool offsets (Tool Offset Active)
UFR
Work offsets (User Frame)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
SINUMERIK Operate (IM9)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents