■When selecting "Discard Data and Continue Sampling"
A new recording file is not saved and data is discarded, and a saving error occurs. (Page 86 If saving a file fails)
To save a new recording file, perform either of the following:
• Reduce the number of recording files in a save destination.
• Increase the upper limit.
*1 For deleting a recording file saved to an SD memory card, refer to the following:
Page 57 Deleting a recording file
Name and save destination of a video file
■File name
The name of a video file is set as follows:
• [I/O No.]_[Network camera No.]_[Date]_[Time].extension
Item name
I/O No.
Network camera No.
Date
Time
Extension
*1 When selecting H.264 for the video codec
Page 42 Video data that can be received
*2 When selecting Motion JPEG for the video codec
Page 42 Video data that can be received
■Save destination
A video file is saved to the following folder:
• CAM_[I/O No.]
Item name
I/O No.
• A generated video file can be played in general-purpose playback tools.
However, do not change the folder, file configuration, or the name of a file in which the video file is stored.
If changed, the video file cannot be played in GX VideoViewer.
• If no network camera is set as a receiving target in the "Video Data Receiving Target Setting" screen, a
video file and CAM_[I/O No.] folder are not generated. (Page 141 Video Data Receiving Target Setting)
1 FUNCTIONS
56
1.1 Recording Function
Setting content
The start I/O number of a camera recorder module
The number of a network camera
• Camera No.1: 1
• Camera No.2: 2
• Camera No.3: 3
• Camera No.4: 4
A date when recording starts for a video file
• YYYYMMDD
A time when recording starts for a video file
• hhmmsssss
The extension of a video file
*1
• .mp4
*2
• .mov
Setting content
The start I/O number of a camera recorder module
*1