Mitsubishi Electric MELSEC iQ-R Series User Manual page 279

System recorder
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Recording start error cause (Un\G1503)
Each value is stored at each timing as follows:
Value
Main module
0 (no error)
• The operating status of the main module switches to
'preparing' after starting the recording function. (It is initialized
to '0' (no error).)
Values other than 0 (error
• A CPU module or the main module cannot start recording
code)
due to an error after starting the recording function.
• There is any sub module with recording target data that
cannot start recording after starting the recording function.
■File saving trigger monitor (Un\G1504)
'1 (satisfied)' is stored during either of the following periods:
Value
Main module
1 (satisfied)
• From when a file saving trigger is satisfied to when saving is
completed in the main module and all sub modules with
recording target data
■Recording files saving (Un\G1505)
Each value is stored at each timing as follows:
Value
Main module
0 (not saving)
• Saving a recording file is completed in the main module and
all sub modules with recording target data.
1 (saving)
• Saving a recording file is started.
■Recording files saving completion (Un\G1508)
Each value is stored at each timing as follows:
Value
Main module
0 (not completed)
• A file saving trigger is satisfied.
• The operating status of the main module switches to
'operating' after starting the recording function. (It is initialized
to '0' (not completed).)
1 (completed)
• Saving a recording file is completed in the main module and
all sub modules with recording target data.
■Recording files saving error (Un\G1509)
Each value is stored at each timing as follows:
Value
Main module
0 (no error)
• A file saving trigger is satisfied.
• The operating status of the main module switches to
'operating' after starting the recording function. (It is initialized
to '0' (no error).)
1 (error exists)
• Saving a recording file fails in the main module.
• Saving a recording file fails in a sub module with recording
target data.
• There is video data that failed to be saved in the main module
and all sub modules with recording target data.
Sub module
• The operating status of the camera recorder module itself
switches to 'preparing' after starting the recording function. (It
is initialized to '0' (no error).)
• The camera recorder module itself cannot start recording due
to an error after starting the recording function.
Sub module
• From when a file saving trigger is satisfied to when saving is
completed in the camera recorder module itself
Sub module
• Saving a recording file is completed in the camera recorder
module itself.
• Saving a recording file is started in the camera recorder
module itself.
Sub module
• A file saving trigger is satisfied.
• The operating status of the camera recorder module itself
switches to 'operating' after starting the recording function. (It
is initialized to '0' (not completed).)
• Saving a recording file is completed in the camera recorder
module itself.
Sub module
• A file saving trigger is satisfied.
• The operating status of the camera recorder module itself
switches to 'operating' after starting the recording function. (It
is initialized to '0' (no error).)
• Saving a recording file fails in the camera recorder module
itself.
• There is video data that failed to be saved in the camera
recorder module itself.
7 CAMERA RECORDER MODULE (DETAILED SPECIFICATIONS)