Error code
Error name
1A81H
IP Address Automatic
Acquisition Update Error
1A82H
IP Address Setting Error
1A83H
DNS Setting Error
1C40H
PTZ Control Request Error
1C50H
PTZ Control Error
1C51H
PTZ Function Unsupported
Error
1C60H
Preset Position Registration
Error
1C70H
Preset Position Deletion Error
1C80H
Preset Position Unregistered
Error
1C90H
Preset Position Execution Error
1CA0H
Preset Position Registration
Count Upper Limit Reach Error
1CB0H
PTZ Authority Mode
Unexecutable Error
1D00H
Module Extended Parameter
Error
Error description
Failed to perform the automatic lease update
processing which is performed when the
lease term of the IP address acquired from
the DHCP server expires.
The setting value of the IP address setting is
incorrect.
The setting value of the DNS setting is
incorrect.
The network camera setting is not written.
Failed to perform the PTZ control of the
network camera.
The target network camera does not support
the PTZ function.
Failed to register the specified preset
position.
Failed to delete the specified preset position.
The specified preset position is not
registered.
Unable to move to the specified preset
position.
The number of preset registration counts
has exceeded the guaranteed maximum
value.
Moving to the preset position was performed
while the PTZ control authority mode is "PTZ
disabled mode".
• A parameter which is not supported by the
firmware version of the target camera
recorder module was written.
• The contents in the module extended
parameter are broken.
Corrective action
Please check the connection cable and status of the
DHCP server (operating status and whether the IP
address to be assigned is allocated).
Please review the IP address setting in the basic
settings of the module parameter.
Please review the DNS setting in the basic settings of
the module parameter.
Please write the module extended parameter with the
engineering tool.
• Please check the operation status of the target
network camera.
• Please check if the connection cable is not
disconnected.
• Please perform the PTZ control again. If the same
error is displayed again, the camera recorder module
may be defective. Please consult your local
Mitsubishi representative.
Please review the network camera specified as the PTZ
control target.
• Please register the preset position again.
• If the same error is displayed again, the camera
recorder module may be defective. Please consult
your local Mitsubishi representative.
• Please delete the preset position again.
• If the same error is displayed again, the camera
recorder module may be defective. Please consult
your local Mitsubishi representative.
Please specify the number of the registered preset
position.
• Please check the operation status of the target
network camera.
• Please check if the connection cable is not
disconnected.
• Please check if the specified preset position No. and
preset position speed are within the settable ranges.
Even if more preset positions are registered, the setting
value cannot be guaranteed.
Please perform moving to the preset position while the
PTZ control authority mode is "PTZ enabled mode" or
"PTZ preset mode".
• Please check the version of the camera recorder
module, use a compatible product, and then write the
module extended parameter again.
• Please write the module extended parameter again
with the engineering tool. If the same error is
displayed again, the camera recorder module may be
defective. Please consult your local Mitsubishi
representative.