7. POSITIONING CONTROL
7.15

Speed-Switching Control

7.15.1

Starting speed-switching control, speed-switching points, end designation

Servo
Instruction
VSTART
Start
End
VEND
ABS-1
End point
ABS-2
address
ABS-3
INC-1
Travel value
INC-2
to end point
INC-3
Speed-
VABS
switching
VABC
point
Downloaded from
ManualsNet.com
(1) After a single control start, the speed is switched for positioning control to the
preset speed-switching points.
(2) The speed-switching points and speed are set by the servo program.
(3) Repeated instructions permit repeated control between any speed-switching
points.
(4) M codes and torque limit values can be changed at each speed-switching point.
Number of
Positioning
Controllable
Method
Axes
1
2
Absolute data
3
1
Incremental
2
3
Absolute data
Incremental
search engine
Items Set by Peripherals
Common
Arc
!
!
!
!
!
7 − 79
Parameter Block
! : Must be set
∆ : Set if required
Others
OK