Mitsubishi Electric SV13/22 Programming Manual page 284

Table of Contents

Advertisement

7. POSITIONING CONTROL
Downloaded from
ManualsNet.com
(3) Setting the axes controlled by the manual pulse generator
(a) The axes controlled by the manual pulse generator are set in the manual
pulse generator axis setting register (D1012).
The value is set as a maximum of three decimal digits, with each digit rep-
resenting an axis from Axis 1 to Axis 4 / Axis 1 to Axis 8.
(The number of digits represents the number of simultaneously controlled
axes.)
Example
Set the following value to control Axis 3 and Axis 4 with the manual pulse
generator.
(4) Manual pulse generator 1-pulse input magnification
(a) The magnification for setting for a 1 pulse input from the manual pulse gen-
erator is set for each axis.
<A172SHCPUN>
1-Pulse Input Mag-
nification
Setting Register
D1016
D1017
D1018
D1019
D1020
D1021
D1022
D1023
<A171SHCPUN>
1-Pulse Input Mag-
nification
Setting Register
D1016
D1017
D1018
D1019
search engine
K34
D1012
MOVP
Axis 3 and Axis 4 designated
Corresponding
Setting Range
Axis No.
Axis 1
Axis 2
Axis 3
Axis 4
1 to 100
Axis 5
Axis 6
Axis 7
Axis 8
Corresponding
Setting Range
Axis No.
Axis 1
Axis 2
1 to 100
Axis 3
Axis 4
7 − 132