7. POSITIONING CONTROL
7.16.1

Setting Pass points using Repeated Instructions

Servo
Instruction
FOR-TIMES
FOR-ON
FOR-OFF
NEXT
[Control Details]
Downloaded from
ManualsNet.com
This section describes the method of designating the pass points used for repeated
execution between pass points.
Number of
Positioning
Controllable
Method
Axes
Setting the start of the repeated range
The start of the repeated range is designated using the following instructions:
(1) FOR-TIMES (number of loops setting)
(a) The designated repeated range is executed the set number of times.
(b) The setting range is (1 to 32767).
If an out-of-range setting between −32768 and 0 is designated, control is
executed with a setting of "1".
(c) The following devices are available to set the number of repetitions:
1) Data register (D)
2) Link register (W)
3) Decimal constant (K)
4) Hexadecimal constant (H)
(2) FOR-ON (loop-out trigger condition setting)
(a) The set repeated range is executed while the designated bit device is ON.
(b) The following devices are available to set the loop-out trigger condition:
1) Input (X)
2) Output (Y)
3) Internal relay (M)/Special relay (SP.M)
4) Latch relay (L)
5) Link relay (B)
6) Annunciator (F)
search engine
Items Set by Peripherals
Common
Arc
Indirect designation
7 − 94
Parameter Block
Others
!
! : Must be set