3. POSITIONING SIGNALS
3.1.2

Axis command signals

Downloaded from
ManualsNet.com
(1) Stop command (M1800+20n)
(a) The stop command is a signal used to stop an axis that is currently being
driven and becomes effective at its leading edge (OFF→ON). (An axis for
which the stop command is ON cannot be started.)
Stop
OFF
command
(M1800 + 20n)
V
Set speed
(b) It can also be used as the stop command when speed control is being
executed.
(For details on speed control, see Section 7.12 or Section 7.13.)
Control Being
Executed
Position control
Speed control (I, II)
JOG operation
Manual pulse
generator operation
Zeroing
POINT
If a stop is executed by turning ON the stop command (M1800+20n) during a
zeroing operation, re-execute the zeroing operation.
If the stop command came ON after the proximity dog came ON in the zeroing
operation, first retract to a position before the point where the proximity dog
comes ON using JOG operation or positioning, and then execute the zeroing
operation again.
search engine
Deceleration processing
Processing when the Stop Command Comes ON
If Control is Being Executed
The axis decelerates to a stop in the
deceleration time set in the parameter
block or servo program.
An immediate stop is executed, with
no deceleration processing.
(1) The axis decelerates to a stop in the deceleration time set in the
parameter block.
(2) A "stop during home position return" error occurs and the error code
(202) is stored in the minor error storage area for each axis.
3 − 13
ON
Stop
command for
designated
Control
axis
when stop
command is
OFF
Stop
If Deceleration Stop Processing is
Being Executed
The stop command is ignored and
deceleration stop processing
continues.
t