• Kodak DryView 8700 + Pacs LINK IMN 9410
-A 310 -T NO -M CUBIC -m ? -S LUT=0?, 2? (?: Site Dependent)
(entered in param member)
78 (entered in pixelPitch member)
14x17
4096 (entered in W member)
5220 (entered in H member)
• Trimming OFF
• Cubic spline interpolation
• Smoothing must be adjusted at the user's site.
• Maximum density: 3.10
• LUT = m, n is designated as the Config Info but m and n are adjusted on-site by the
Kodak service engineer. Basically, adjustment is performed to achieve a linear output.
• Kodak DryView 8700 + GW
-A 310 -T NO -M CUBIC -m ? -S LUT=?, ? (?: Site Dependent)
(entered in param member)
78 (entered in pixelPitch member)
14x17
4096 (entered in W member)
5220 (entered in H member)
• Trimming OFF
• Cubic spline interpolation
• Smoothing must be adjusted at the user's site.
• Maximum density: 3.10
• LUT = m, n is designated as the Config Info but m and n are adjusted on-site by the
Kodak service engineer. Basically, adjustment is performed to achieve a linear output.
• Kodak DryView 8700+8800
-A 320 -T NO -M CUBIC –S "LUT=m, n"-m (on-site adjustment)
(entered in param member)
78 (entered in pixelPitch member)
4096 (entered in W member)
5220 (entered in H member)
• Trimming OFF
• Cubic spline interpolation
• Maximum density: 3.20
• LUT = m, n is designated as the Config Info but m and n are adjusted on-site by the
Kodak service engineer. Basically, adjustment is performed to achieve a linear output.
• The Kodak service engineer is responsible for setting the smoothing type on-site since it
can be changed with each printer.
• The rest is done by the printer itself.