Measurement-Period; Mac-Address; Type; Table 30 Measurement-Period Command - Nokia 7302 Manual

Intelligent services access manager/fttn/fx, fd 100/320gbps nt and fx nt ihub services
Hide thumbs Also See for 7302:
Table of Contents

Advertisement

FD 100/320Gbps NT and FX NT IHub Services Guide
3.17.4.14
Table 30
3.17.4.15
Table 31
3.17.4.16
Table 32
(1 of 2)
Issue: 13

measurement-period

measurement-period command
Item
Description
Syntax
measurement-period period
Context
configure>eth-cfm>y1731pm>domain
Description
The value of measurement-period specifies the time after which the synthetic loss calculation
is made periodically. If the value of this object is set to 'X' seconds, loss measurement
calculations are done after every 'X' seconds. This includes the default SLM timeout of 5
seconds in which the agent will not transmit any further SLM PDUs and will wait for the
response from remote node. Upon the expiration of the timeout, the agent assumes that the
message response will not be received. Any response received after the timeout period has
expired is silently discarded. This parameter is optional and is valid only if type – two-way-slm.
This can be set only when admin status is set to disabled.
The no form of the command reverts the value to the default.
Default
300 seconds
Parameters
period — [60|300]

mac-address

mac-address command
Item
Description
Syntax
mac-address mac-address
Context
configure>eth-cfm>y1731pm>domain
Description
Specifies the target unicast MAC address for the y1731pm session.
The no form of the command reverts the value to the default
Default
00:00:00:00:00:00
Parameters
period — [xx:xx:xx:xx:xx:xx or xx-xx-xx-xx-xx-xx]

type

type command
Item
Description
Syntax
type type
3HH-11985-AAAA-TQZZA
Services Overview
93

Hide quick links:

Advertisement

Table of Contents
loading