8.12.1.14
Table 219
8.12.1.15
Table 220
(1 of 2)
Issue: 10
Item
Description
Default
7
Parameters
priority — <0,1,2...7>

period

period command
Item
Description
Syntax
period period
Context
configure>eth-cfm>y1731pm>domain
Description
The value of period specifies the time to wait between the transmission of one OAM request
and the next. This parameter can be set only when admin status is set to disabled. The
applicability, range, and default value of this object vary with type, as described below.
The no form of the command reverts the value to the default.
Default
two-way-slm — 1
two-way-delay — 1
single-end-loss — 60
Parameters
two-way-slm (SLM) — 1...10
two-way-delay (DM) — 1...10
single-end-loss (LM) — 60...300

measurement-period

measurement-period command
Item
Description
Syntax
measurement-period period
Context
configure>eth-cfm>y1731pm>domain