Table 158 Remote-Age Command; Table 159 Send-Flush-On-Failure Command; Remote-Age - Nokia 7302 Manual

Intelligent services access manager/fttn/fx, fd 100/320gbps nt and fx nt ihub services
Hide thumbs Also See for 7302:
Table of Contents

Advertisement

FD 100/320Gbps NT and FX NT IHub Services Guide
5.16.2.34
Table 158
5.16.2.35
Table 159
Issue: 13

remote-age

remote-age command
Item
Description
Syntax
remote-age aging-timer
no remote-age
Context
configure>service>vpls
Description
Specifies the aging time for remotely learned MAC addresses in the forwarding database
(FDB) for the Virtual Private LAN Service (VPLS) instance. In a VPLS service, MAC addresses
are associated with a Service Access Point (SAP) or with a Service Distribution Point (SDP).
MACs associated with an SAP are classified as local MACs, and MACs associated with an
SDP are remote MACs.
Like in a layer 2 switch, learned MACs can be aged out if no packets are sourced from the
MAC address for a period of time (the aging time). In each VPLS service instance, there are
independent aging timers for local learned MAC and remote learned MAC entries in the FDB.
The remote-age timer specifies the aging time for remote learned MAC addresses. To reduce
the amount of signaling required between switches configure this timer larger than the
local-age timer.
The no form of this command returns the remote aging timer to the default value.
Default
remote age 900 — Remote MACs aged after 900 seconds
Parameters
aging-timer — The aging time for remote MACs expressed in seconds.
Values 60 — 86400
send-flush-on-failure
send-flush-on-failure command
Item
Description
Syntax
[no] send-flush-on-failure
Context
configure>service>vpls
Description
This command enables sending out "flush-all-from-ME" messages to all LDP peers included in
affected VPLS, in the event of physical port failures or "oper-down" events of individual SAPs.
This feature provides an LDP-based mechanism for recovering a physical link failure in a
dual-homed connection to a VPLS service. This method provides an alternative to RSTP
solutions where dual homing redundancy and recovery, in the case of link failure, is resolved
by RSTP running between a PE router and CE devices. If the endpoint is configured within the
VPLS and send-flush-on-failure is enabled, flush-all-from-me messages will be sent out only
when all spoke SDPs associated with the endpoint go down.
This feature cannot be enabled on management VPLS.
Default
no send-flush-on-failure
3HH-11985-AAAA-TQZZA
Virtual Private LAN Service
271

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

73307360

Table of Contents