Symbol
Parameter name Arguments
MEAutoTransition
ME?
Time?
ABusXpt?
BBusXpt?
MECut
ME?
KeyAutoTransition
ME?
Key?
Time?
Direction?
KeyCut
ME?
Key?
Direction?
Play
Device?
ME1 to ME3, PP
Current (a), 1 to 999
Current (a), 1 to 128
Current (a), 1 to 128
ME1 to ME3, PP
ME1 to ME3, PP
Key1 to Key4
Current (a), 1 to 999
ToOn(a), ToOff(b), Any(c)
ME1 to ME3, PP
Key1 to Key4
ToOn(a),
ToOff(b),
Any(c)
1 to 12
Description
Applicable switcher bank
Transition rate (number of
frames)
(a): Mode in which the
current value set on the
transition control block is
used
A bus or B bus cross-point
button number. Use the
button number of the main
table set in the Xpt Assign
menu.
(a): Mode in which the
cross-point number set for
the current A bus or B bus is
used
Applicable switcher bank
Applicable switcher bank
Key of the applicable
independent key transition
control block
Transition rate (number of
frames)
(a): Mode in which the
current value set on the
independent key transition
control block is used
Transition execution mode
(a): Key is inserted
(b): Key is deleted
(c): Transition is always
executed
Applicable switcher bank
Key of the applicable
independent key transition
control block
Transition execution mode
(a): Key is inserted
(b): Key is deleted
(c): Transition is always
executed
Applicable device
Macro File Editing Rules
445