• When the operating bank order is changed, the state of region selection
button assignment in the numeric keypad control block also changes
correspondingly.
3
For the selected Bank number, in the <M/E Operation> group, select one
of the following.
Enable: Enable panel display and operation of the operating bank.
Disable: Enable only panel display, and disable operation of the operating
bank.
Inhibit: Disable both the panel display and operation of the operating
bank.
Note
When this is set to Inhibit, snapshots of the operating bank are not recalled.
Assigning two M/E banks to one M/E bank
Use the following procedure.
1
In the Panel>Config menu, select the M/E bank for which you want to
make the setting.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Knob
1
For example, if the furthest bank from you is assigned to M/E-1, and you
want no shift button operation for the bank, select 1 for Bank.
2
Press [Dual M/E Assign].
This assigns the furthest M/E bank from you to the unshifted cross-points
and the M/E bank in front of it to the shifted cross-points. For fader lever
operations, only the M/E bank closer to you is enabled.
To return to the original assignment
Interchange the operating bank order (see page 248).
Parameter Adjustment
Bank
Selection of position of operating bank for
which you want to make the setting
Setup Relating to Operations From the Control Panel
Setting values
1 to 4
249