Rt - Ram Test - GE 68K System User Manual

System monitor
Table of Contents

Advertisement

68K System Monitor
User's Guide

RT - RAM Test

þ
CPM
Platform
Use this command to perform a non-destructive read-write test of specified RAM
Description
memory.
The test may be for the entire RAM or NVRAM regions, or for a specified range of
values. You may also select to run the test for a set number of loops, or to loop
infinitely.
Note:
Syntax
Below is usage and syntax information for this command
Command Format
Variables
Parameters
Example
General
Full Release
þ
þ
D20
D20 ME
D20 Base
D20 Base
If the input range is not on long word boundary, set the range ending
address to the first lesser word boundary.
CPM / D20:
CCU / CCUME:
D25:
/v
=
/n
=
/s
=
/gv
=
/gn
=
beg_addr =
end_addr =
#loops
=
i
=
Type rt /gn 510000 5100b0 25000 and press
Results: This tests the integrity of the global non-volatile
(static) RAM between the memory range of 510000
and 5100b0 repeatedly for 25,000 times.
The system simply returns the prompt when it
successfully completes this instruction.
If the test fails, the system displays an error message
before returning to the prompt.
SWM0023-1.00 -2
þ
þ
D20/200
CCU Base
rt / (v | n)
rt / (v | n | gv | gn) [beg_addr
end_addr [(#loops | i)]]
rt / (v | n | s) [beg_addr
end_addr [(#loops | i)]]
volatile (static) RAM
non-volatile RAM (NVRAM)
destructive sequential test
global volatile (static) RAM
global non-volatile RAM (NVRAM)
first address of memory range (in hexadecimal)
end address of memory range (in hexadecimal)
number of times to execute the finite loop for the
specified memory (in decimal) before stopping
use infinite loop
GE Energy Services
þ
D20/200 ME
D25
CCU Base
.
ENTER
Continued on next page