Mitsubishi Electric MELDAS C6 Parameter Manual page 76

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

#
Items
2007 G1tL
G1 time
constant
(linear)
2008 G1t1
G1 time
constant
(primary
delay)
Second-step
time
constant for
acceleration
and
deceleration
by software
2009 G1t2
6. Axis Specifications Parameters
6.1 Axis Specifications Parameters
Details
Set up a linear control time constant for cutting
acceleration and deceleration.
The time constant is validated when LC (cutting feed
with linear acceleration and deceleration) or F
(acceleration and deceleration by software) is selected
in acceleration or deceleration mode "#2003 smgst."
Speed
G1tL
Set up the primary delay time constant for cutting
acceleration and deceleration.
The time constant is validated when C1 (cutting feed
with the primary delay) or C3 (cutting feed with
exponential acceleration and linear deceleration) is
selected in acceleration or deceleration mode "#2003
smgst."
When acceleration or deceleration by software is
selected, the second stage time constant is used.
<Cutting feed with primary delay>
Speed
G1t1
<Cutting feed with exponential
acceleration and linear deceleration>
Speed
G1t1
<Acceleration/deceleration by software>
Speed
G1t1 G1t1
G1t1
G1tL
Not used.
70
Get other manuals https://www.bkmanuals.com
Setting range (unit)
1 to 4000 (ms)
Tim e
G1tL
1 to 5000 (ms)
Time
G1t1
Time
2
G1t1
Time
G1t1
G1tL

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents