Items
1265
ext01
Command
(PR)
(bit0)
format
1266
ext02
(PR)
1267
ext03
G code type
(PR)
(bit0)
1268
ext04
(PR)
1269
ext05
(PR)
1270
ext06
(PR)
1271
ext07
Mirror image
(PR)
(bit0)
operation
ext07
Address
(bit1)
specifying
fixed-cycle
repetition
count (For M
system only)
ext07
F-command
(bit2)
unit
5. Base Specifications Parameters
Details
Select the command format.
0: Conventional format
Not used.
Select the G code type.
This parameter is valid when 1 is set in "#1265 ext01 bit
0 (command format)".
Not used.
Not used.
Not used.
Select the type of mirror image operation. Not applied
to this CNC.
0: Type 1
• The program mirror image, external mirror
image, and parameter mirror image are
exclusive to each other.
• An increment command moves the image to
the position indicated by the move amount with
the sign inverted.
1: Type 2
• Mirror image operation is enabled when the
program mirror image (G51.1) command is
issued or when the external signal or
parameter is ON.
• An increment command moves the image to
the position determined by applying the mirror
image to the absolute program coordinates.
Specify the address that specifies the fixed-cycle
repetition count. Not applied to this CNC.
0: Address L only
1: Addresses K and L
If addresses K and L are specified simultaneously, the
data at address K is used for operation.
Specify the unit to be used if a thread cutting read
command contains on decimal point. Not applied to this
CNC.
0: Type 1 (conventional specifications)
F1 → 1 mm/rev, 1 inch/rev
1: Type 2
F1 → 0.01 mm/rev, 0.0001 inch/rev
53
Get other manuals https://www.bkmanuals.com
Setting range (unit)
0
0/1
0/1
(Default: 0)
0/1
(Default: 0)
0/1
(Default: 0)