Mitsubishi Electric MELDAS C6 Parameter Manual page 256

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

No.
Items
3321
SP121 MPCSH Orientation
3322
SP122 MPCSL
3323
SP123
to
to
3325
SP125
3326
SP126 MPGH
3327
SP127 MPCSM Orientation
3328
SP128 OXKPM Position
8. Spindle Parameters
8.4 MDS-C1-SPM
Set the compensation magnification of the
deceleration
orientation deceleration rate for the H winding.
rate H
winding
Orientation deceleration rate for the H
compensa-
winding
tion magnifi-
= SP006 × SP121/256
cation
When set to "0", will become the same as
SP006.
Orientation
Set the compensation magnification of the
deceleration
orientation deceleration rate for the L winding.
rate L
winding
Orientation deceleration rate for the L
compensa-
winding
tion magnifi-
= SP006 × SP122/256
cation
When set to "0", will become the same as
SP006.
Use not possible.
Orientation
Set this to set the orientation position loop
position gain
gain for the coil changeover motor to the M
M coil com-
coil's unique value.
pensation
Set this to set the orientation deceleration rate
deceleration
for the coil motor to the M coil's unique value.
rate M coil
compensa-
tion
Set the M coil gain magnification to be used
loop gain
after in-position when gain changeover is
magnifi-
valid (SP097: SPEC0-bitC=1) during
cation after
orientation.
orientation
gain
change-
over (M coil)
250
Get other manuals https://www.bkmanuals.com
Details
Setting
Standard
range
setting
0 to 2560
0
(1/256-fol
d)
0 to 2560
0
(1/256-fol
d)
0
0
0 to 2560
0
(1/256-
fold)
0 to 2560
0
(1/256-
fold)
0 to 2560
0
(1/256-
fold)