7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
No.
Items
2226 SV026
Excessive
OD2
error
detection
width during
servo OFF
7. Servo Parameters
Details
(Continued from the previous page)
bit
8
Set the detector type. Set position detector type for "pen", and
speed detector type for "ent". In the case of the semi-closed
9
ent
loop control, set the same value for "pen" and "ent".
A
B
pen setting ent setting
C
0
D
pen
1
E
2
F
3
4
5
6
7
8
9
A
B
C
D
E
F
Set the excessive error detection width when servo ON.
For the standard setting, refer to the explanation of
SV023 (OD1).
When "0" is set, the excessive error detection will not be
performed.
142
Get other manuals https://www.bkmanuals.com
Explanation
Detector model name
OHE25K (Only for
0
MDS-B-Vx), OSE104
OHA25K (Only for
1
MDS-B-Vx), OSA104
2
OSE105, OSA105
Equipped to HA053, HA13
3
(Only for MDS-B-Vx)
Setting
OHE25K-ET, OSE104-ET
impossible
Setting
OHA25K-ET, OSA104-ET
impossible
Setting
OSE105-ET, OSA105-ET
impossible
Setting
impossible
Relative position detection
Setting
scale, MP type (Mitsubishi
impossible
Heavy Industries)
Setting
AT41 (Mitsutoyo), FME type,
impossible
FLE type (Futaba)
Setting
AT342 (Mitsutoyo)
impossible
Setting
impossible
The setting of the slave axis in
C
the speed/current
(Current
synchronization control.
synchroni-
When the master axis is the
zation)
semi-closed control.
Setting
impossible
Setting
impossible
Setting
impossible
Setting range
0 to 32767
(mm)