Mitsubishi Electric MELDAS C6 Parameter Manual page 226

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

No.
Items
3325 SP125 MGD2
Magnetic
sensor
switching
point
3326
SP126
to
to
3328
SP128
3329
SP129 SPECC C-axis
(PR)
specifica-
tions
3330 SP130 PGC1
First
position
loop gain
for cutting
on C-axis
3331 SP131 PGC2
Second
position
loop gain
for cutting
on C-axis
8. Spindle Parameters
8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
This parameter is used for adjustment of
orientation operation of the magnetic sensor.
Set the distance dimension from the target stop
point at switching from position feedback to
magnetic sensor output.
Normally, set a value that is approx. 1/2 of the
value defined in SP124.
Use not possible.
Set the C-axis specifications in bit units.
F
E
D
C
zrtn ptyp fb9x zrtd zrn2
7
6
5
4
vg8x
fdir
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
fclx
Closed loop
0
adin
Interpolation A/D
1
compensation invalid
rtrn
Position monitor during
2
ready OFF invalid
phos
Normal
3
(no compensation)
4
fdir
Position detector
5
polarity (+)
6
vg8x
Speed gain × 1/8 during
7
torque limit valid
ztyp
Z-phase type: Normal
8
start up
zdir
Z-phase rising polarity
9
(+)
A
B
zrn2
This is used by Mitsubishi.
Set to "0" unless particularly designated.
C
zrtd
fb9x
Speed feedback
D
Standard (PLG)
ptyp
Position control switch
E
type: After zero point
return
zrtn
Zero point return
F
direction: CCW
Set the position loop gain when the first gain is
selected for C axis cutting.
Set the position loop gain when the second gain
is selected for C axis cutting.
220
Get other manuals https://www.bkmanuals.com
Details
B
A
9
8
zdir
ztyp
3
2
1
0
phos rtrn
adin
fclx
Semi-closed loop
(Gear 1 : 1 only)
Interpolation A/D
compensation valid
Position monitor during
ready OFF valid
Vx4 synchronization
compensation valid
Position detector polarity
(–)
Speed gain × 1/8 during
torque limit invalid
Z-phase type: Start up only
Z-phase rising polarity (–)
Speed feedback
90,000 pulse detector
Position control switch type:
After deceleration stop
Zero point return direction:
CW
Setting
Standard
range
setting
1 to 10000 Standard
magnetizin
g element:
384
Small
magnetizin
g element:
220
0
0
0000
1 to 100
15
(1/s)
1 to 100
15
(1/s)