Items
1301 nrfchk
Origin
neighboring
check
method
1501 polyax
Rotational
(For L
tool axis
system
number
only)
1505 ckref2
Second
reference
point return
check
1510
DOOR_H
Shorten door
interlock II
axis stop
time
DOORPm
1511
Signal input
device 1 for
door interlock
II: for each
part system
DOORPs
1512
Signal input
device 2 for
door interlock
II: for each
part system
5. Base Specifications Parameters
Details
Select the high-speed check method of the origin
neighboring signal.
0: Does not check positions near the origin at high
speeds. (Conventional specifications)
1: Checks positions near the origin at high speeds
using command machine positions.
2: Checks positions near the origin at high speeds
using detector feedback positions.
Specify the number of the rotational tool axis (servo
axis) used for polygonal machining (G51.1). Specify 0
when polygonal machining is not performed. A value
exceeding the base specification parameter "#1002
axisno" cannot be specified.
This parameter is valid when the G code system is 6 or
7 (7 or 8 is set in base specification parameter "#1037
cmdtyp").
Specify the trigger for a check at the specified position
in manual second reference point return mode.
0: Completion of spindle orientation
1: Generation of second reference point return
interlock signal
Specify whether to shorten the time during which the
axis is stopped when the door is opened.
0: Uses the conventional axis stop time.
1: Shortens the axis stop time.
(Note) When the door interlock II signal is input via a
ladder, the conventional axis stop time is used.
Specify the fixed device number (X??) for door
interlock II signal input for each part system.
A device number from X001 to X3FF can be specified.
Device number 000 is invalid.
Specify device number 100 when using no fixed device
number for door interlock II signal input.
(Note) The setting range of this parameter has been
expanded on the software Ver.D0 and later.
Related parameter: #1154 pdoor (Door interlock II for
each part system)
Specify the fixed device number (X??) for door
interlock II signal input for each part system.
(Specify the same value as that of #1155.)
(Note) The setting range of this parameter has been
expanded on the software Ver.D0 and later.
Related parameter: #1154 pdoor (Door interlock II for
each part system)
58
Get other manuals https://www.bkmanuals.com
Setting range (unit)
0 to 2
0 to controlled axis
number
0/1
0/1
000 to 3FF
(hexadecimal)
000 to 3FF