Mitsubishi Electric MELDAS C6 Parameter Manual page 53

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

#
Items
1226 aux10
Tool compen-
sation data for
(bit0)
external
workpiece
coordinate
offset
measurement
aux10
Optional
(bit1)
block skip
type
aux10
Single block
(bit2)
stop timing
aux10
(bit3)
aux10
S command
(bit4)
during
constant
surface
speed
aux10
Dog/OT
(bit5)
signal
arbitrary
assignment
valid
5. Base Specifications Parameters
Details
Select the tool offset data to be used for external
workpiece coordinate offset measurement.
0: Tool length data and nose wear data
1: Tool length data
Specify whether to enable optional block skipping in the
middle of a block.
0: Enable block skipping only at the beginning of a
block.
1: Enable block skipping at the beginning of the
block and in the middle of a block.
Specify the time at which the single block signal is
activated.
0: When the signal goes on while automatic
operation is starting, the block stops after it is
finished.
1: When the signal is on at the end of the block, the
block stops.
Not used.
Specify whether to output a strobe signal when the S
command is issued in constant surface speed mode.
0: Output no strobe signal in constant surface
speed mode.
1: Output strobe signals in constant surface speed
mode.
Specify whether to enable the arbitrary allocation
parameter for the origin dog and H/W OT.
0: Disable arbitrary allocation. (Fixed devices are
valid.)
Note that when the backup module for
powerfailure is mounted, all dog signals
allocation will be disabled, however, OT signals
will be allocated to the fixed devices.
1: Enable arbitrary allocation. (Devices specified by
#2073 to #2075 parameters)
47
Get other manuals https://www.bkmanuals.com
Setting range (unit)
0/1
0/1
0/1
0
0/1
0/1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t