Mitsubishi Electric MELDAS C6 Parameter Manual page 201

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

No.
Items
3382
SP182 VCSS
Change
(PR)
starting speed
of variable
speed loop
proportional
gain at
spindle
synchroniza-ti
on
3383 SP183 SYNV
Sync match-
ing speed at
spindle syn-
chronization
3384
SP184 FFCS
Acceleration
(PR)
rate feed
forward gain
at spindle
synchronizati
on
3385 SP185 SINP
Spindle sync
in-position
width
3386
SP186 SODR
Excessive
(PR)
error width at
spindle
synchronizati
on
3387
SP187 IQGS
Current loop
(PR)
gain magnifi-
cation1 at
spindle syn-
chronization
3388
SP188 IDGS
Current loop
(PR)
gain magnifi-
cation 2 at
spindle syn-
chronization
3389
SP189
to
to
3392
SP192
8. Spindle Parameters
8.2 MDS-B-SPJ2
Details
Set the speed for starting change of speed
loop proportional gain at spindle
synchronization.
SP178
SP178×
(SP181/100)
SP182
For changeover from the speed loop to the
position loop at spindle synchronization, set
a speed command error range for output of
the sync speed matching signal.
Set the acceleration rate feed forward gain
at spindle synchronization.
This parameter is used only with the SPJ2.
Set the position error range for output of the
in-position signal at spindle
synchronization.
Set the excessive error width at spindle
synchronization.
Set the magnification of current loop gain
(torque component) at spindle
synchronization.
Set the magnification of current loop gain
(excitation component) at spindle
synchronization.
Not used. Set to "0".
195
Get other manuals https://www.bkmanuals.com
Proportional gain
Speed
SP017
Setting
Standard
range
setting
0 to 32767
0
(r/min)
0 to 1000
20
(r/min)
0 to 1000
0
(%)
1 to 2880
16
(1/16°)
1 to 32767
32767
(1/4 pulse)
(1 pulse
=0.088°)
1 to 1000
100
(%)
1 to 1000
100
(%)
0
0

Advertisement