Items
1066
JOG_HP
Select JOG
activation
(+) device
1067
JOG_HN
Select JOG
activation
(−) device
1068
slavno
Slave axis
(PR)
number
1069
no_dsp Axis with no
(PR)
counter
display
1070 axoff
Axis
removal
JOG_D ±JOG
1071
(PR)
activation
signal
device
name
5. Base Specifications Parameters
Details
Specify the number of the device that inputs +JOG
activation signals. The device type is specified by
"#1071 JOG_D". The effective range of set values vary
depending on the device type. A value outside of the
effective range is invalid if specified.
(Note) The setting range of this parameter has been
expanded on the software Ver.D0 and later.
Specify the number of the device that inputs -JOG
activation signals. The device type is specified by
"#1071 JOG_D". The effective range of set values vary
depending on the device type. A value outside of the
effective range is invalid if specified.
(Note) The setting range of this parameter has been
expanded on the software Ver.D0 and later.
Specify the axis number of a slave axis to be
synchronized. The axis number is an NC number
excluding the spindle and PLC axis.
Two or more slave axes cannot be set up for one
master axis.
This parameter "slavno" cannot be set up for a slave axis.
A multiple part system cannot be set up so that the
relation between the master and slave axes extends
over a part system.
Set up an axis that displays no counter. This option is
valid on the counter display screen (e.g. POSITION
screen).
Define an axis that enables axis removal control.
Specify the number of the device that inputs ±JOG
activation signals.
0
: X device
1 or 2: M device
Set the JOG_HP (#1066) and JOG_HN (#1067)
parameters according to this device specification
parameter.
(Note) The setting range of #1066 and #1067
parameters has been expanded on the software
Ver.D0 and later.
22
Get other manuals https://www.bkmanuals.com
Setting range (unit)
X: 0000 to 03FF
(hexadecimal)
M: 0000 to 8191
(decimal)
X: 0000 to 03FF
(hexadecimal)
M: 0000 to 8191
(decimal)
0: No slave axis
1 to 6: First to
sixth axes
0: Displays the
counter
1: Does not
display the
counter.
0: Disables axis
removal.
1: Enables axis
removal
0 to 2