Mitsubishi Electric MELDAS C6 Parameter Manual page 67

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

#
Items
1929
Port number
(PR)
1930
Speed 10M/auto
(PR)
1931
IP address(2)
(PR)
1932
Subnet mask(2)
(PR)
1933
Port number(2)
(PR)
1934
Speed(2) 10M/auto
(PR)
(Note1) When two Ethernet cards are mounted, make sure not to use IP address on the same network
IDs.
The cards are regarded as "same network IDs" when the area masked (validated) by "Subnet
mask" parameter is the same as another.
5. Base Specifications Parameters
Details
Set the HMI connection port No.
(Set the default value 64758 unless particularly required.)
Set the communication rate.
0: Fixed to "10Mbyte"
1: Recognized whether "10Mbyte" or "100Mbyte"
automatically and set.
Set NC's IP address.
Set for the card mounted on the 2nd channel when
2-channel connection is used on the Ethernet
communication. (Note1)
Set sub-net mask.
Set for the card mounted on the 2nd channel when
2-channel connection is used on the Ethernet
communication. (Note1)
Set the HMI connection port No.
(Set the default value 64758 unless particularly required.)
Set for the card mounted on the 2nd channel when
2-channel connection is used on the Ethernet
communication. (Note1)
Set the communication rate.
0: Fixed to "10Mbyte"
1: Recognized "10Mbyte" or "100Mbyte"
automatically and set.
Set for the card mounted on the 2nd channel when
2-channel connection is used on the Ethernet
communication. (Note1)
61
Get other manuals https://www.bkmanuals.com
Setting range (unit)
0 to 65535
0/1
Set these according to
connection environ-
ment's network
regulations.
0 to 65535
0/1