No.
Items
3243
SP043 TRNG Synchronous
(PR)
tapping, spindle
synchronous
detector range
3244
SP044 TRAN
NC communi-
(PR)
S
cation
frequency
3245 SP045 CSNT Dual cushion
timer
3246
SP046 CSN2 Speed
(PR)
command dual
cushion
3247
SP047 SDTR Speed
(PR)
detection reset
value
3248
SP048 SUT
Speed reach
(PR)
range
3249 SP049 TLM2
Torque limit 2
3250 SP050 TLM3
Torque limit 3
3251 SP051 TLM4
Torque limit 4
3252 SP052 TLM5
Torque limit 5
3253 SP053 TLM6
Torque limit 6
3254 SP054 TLM7
Torque limit 7
3255
SP055 SETM Excessive
(PR)
speed deviation
timer
8. Spindle Parameters
8.4 MDS-C1-SPM
This parameter is used to set the
synchronous tapping or spindle synchronous
detector range.
Set "0" for this parameter.
Set a frequency of data communication with
NC.
Set the cycle to add the increment values in
the dual cushion process.
When this setting value is increased, the dual
cushion will increase, and the changes in the
speed during acceleration/deceleration will
become gradual.
For an acceleration/deceleration time
constant defined in SP019 (CSN1) , this
parameter is used to provide smooth
movement only at the start of
acceleration/deceleration.
As the value of this parameter is smaller, it
moves smoother but the
acceleration/deceleration time becomes
longer.
To make this parameter invalid, set "0".
Set the reset hysteresis width for a speed
detection set value defined in SP020 (SDTS).
Set the speed deviation rate with respect to
the commanded speed for output of the
speed reach signal.
Set the torque limit rate for the torque limit
signal 010.
Set the torque limit rate for the torque limit
signal 011.
Set the torque limit rate for the torque limit
signal 100.
Set the torque limit rate for the torque limit
signal 101.
Set the torque limit rate for the torque limit
signal 110.
Set the torque limit rate for the torque limit
signal 111.
Set the timer value until the excessive speed
deviation alarm is output.
The value of this parameter should be longer
than the acceleration/deceleration time.
243
Get other manuals https://www.bkmanuals.com
Details
Setting
Standard
range
setting
0 to 7
0
0 to 32767 Standard:
0
Special:
1028
0 to 1000
0
(ms)
0 to 1000
0
0 to 1000
30
(r/min)
0 to 100
15
(%)
1 to 120
20
(%)
1 to 120
30
(%)
1 to 120
40
(%)
1 to 120
50
(%)
1 to 120
60
(%)
1 to 120
70
(%)
0 to 60 (s) 12