Mitsubishi Electric MELDAS C6 Parameter Manual page 40

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

#
Items
1152 I_G20
Initial
command
unit
1154
pdoor
Door
(PR)
interlock II
(for each part
system)
5. Base Specifications Parameters
Details
Specify whether the default mode after power-on or
resetting, inch command or metric command mode.
0: Metric command (G21 command state)
1: Inch command (G20 command state)
Valid when reset input is made.
Related parameter: Bit 6 "Select setting and display
unit" of #1226
Specify whether to control door interlock II
independently for each of the two part systems.
When door interlock II is controlled for each part
system of the two part systems, part system 1 is
connected to SERVO1 of the base I/O unit and part
system 2 is connected to SERVO2 of the base I/O unit.
C6/C64 unit
SERVO1
AMP
SERVO2
AMP
When the auxiliary axis (MR-J2-CT) is used, connect it
to the SERVO2 side (after the spindle). This validates
door interlock II of part system 2.
0: Do not use door interlock II independently for
each part system.
1: Use door interlock II independently for each part
system.
When 0 is specified for this parameter, "Signal input
device 1 for door interlock II (#1155 DOOR_m)" and
"Device number 2 for door interlock II signal input
(#1156 DOOR_s) are valid. When 1 is specified,
"Signal input device 1 for door interlock II: for each part
system (#1511 DOORPm)" and "Signal input device 2
for door interlock II: for each part system (#1512
DOORPs)."
34
Get other manuals https://www.bkmanuals.com
AMP
Part system 1
AMP
AMP
AMP
Part system 2
Setting range (unit)
0/1
0/1