Mitsubishi Electric MELDAS C6 Parameter Manual page 42

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

#
Items
1169 system
Part system
name
name
1170 M2name Second
miscellane-
ous code
1171 taprov
Tap retract
override
1172 tapovr
Tap retract
override
1173 dwlskp
G04 skip
condition
1174 skip_F
G31 skip
speed
5. Base Specifications Parameters
Details
Set the name of each part system.
This must be set when using the multiple part system.
This name is displayed on the screen only when the
part systems must be identified.
Use a max. of four alphabetic characters or numerals.
Set this address code when using the 2nd miscellane-
ous command. Set an address with A‚ B and C that is
not used with "#1013 axname" or "#1014 incax".
Set the tap retract override value for the synchronous
tap.
Set the override value when leaving the tap end point in
the synchronous tap cycle.
The setting range is 1 to 999‚ and the unit is %.
When a value less than 100 is set‚ it will be judged as
100%.
Specify the skip signal for ending the G04 (dwell)
command.
Skip signals
Setting
SKIP3
SKIP2
×
×
0
×
×
1
×
×
2
×
×
3
×
4
×
5
×
6
×
7
×
8
×
9
×
10
×
11
12
13
14
15
Skip when
signal is input.
Specify the feedrate when there is no F command in
the program at G31 (skip) command.
36
Get other manuals https://www.bkmanuals.com
SKIP1
SKIP0
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Setting range (unit)
A max. of four
alphabetic
characters or
numerals.
A, B, C
1 to 100 (%)
1 to 999 (%)
0 to 15
1 to 999999
(mm/min)