No.
Items
3234
SP034 SFNC2 Spindle
(PR)
function 2
3235
SP035 SFNC3 Spindle
(PR)
function 3
8. Spindle Parameters
8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Details
Set the spindle function 2 in bit units.
F
E
D
C
7
6
5
4
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
mts1
Special motor constant
0
invalid
invm
A general-purpose
1
motor FV control invalid
mkch Coil switch function
2
invalid
mkc2 Coil switch specification
3
2 invalid
4
5
6
7
8
9
A
B
C
D
E
F
(Note1) To validate bit3(mkc2), NC side needs to prepare.
(Note2) Always turn the bit2 at the same time to use bit3.
Set the spindle function 3 in bit units.
F
E
D
C
7
6
5
4
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
hwid
H-coil wide-range
0
constant output invalid
lwid
L-coil wide-range
1
constant output invalid
2
hbsd
H-coil base slide invalid
3
lbsd
L-coil base slide invalid
4
5
6
7
8
(Used with SPJ.)
9
A
B
C
D
E
F
205
Get other manuals https://www.bkmanuals.com
B
A
9
8
3
2
1
0
mkc2 mkch invm mts1
Special motor constant
setting valid
A general-purpose
motor FV control valid
Coil switch function valid
Coil switch specification
2 valid (Note1) (Note2)
B
A
9
8
3
2
1
0
lbsd hbsd lwid hwid
H-coil wide-range
constant output valid
L-coil wide-range
constant output valid
H-coil base slide valid
L-coil base slide valid
Setting
Standard
range
setting
0000 to
000C
FFFF
HEX setting
0000 to
0000
FFFF
HEX setting