Mitsubishi Electric MELDAS C6 Parameter Manual page 48

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

#
Items
1210 RstGmd Modal G
code reset
1211 FHtyp
Feed hold
stop type
1212 FHno
Feed hold
external
signal
device
1216 extdcc
External
deceleration
level
1217 aux01
5. Base Specifications Parameters
Details
L system
0
Group 1 Move G modal
1
Group 2 Flat selection modal
2
Group 3 Absolute/increment command modal
3
Group 4 Barrier check modal
4
Group 5 Feed G modal
5
Group 6 Inch/metric modal
6
Group 7 Nose radius compensation modal
7
8
9
Group 10 Fixed cycle return command modal
A
B
Group 12 Workpiece coordinate system modal
C
Group 13 Cut modal
D
E
F
10
Group 17 Constant surface speed control command modal
11
Group 18 Balance cut
12
13
Group 20 Spindle 2 control modal
14
Group 15 Double-turret mirror image
15
16
17
18
19
1A
1B
1C
1D
1E
1F
Specify the type of the external signal used for feed
hold.
0: Disable the external signal.
1: Enable the external signal (contact A)
2: Enable the external signal (contact B)
Specify the number (X??) of the device used to input
the feed hold signal.
(Note) The setting range of this parameter has been
expanded on the software Ver.D0 and later.
Use an upper limit value at the feedrate indicated when
validating external deceleration signals.
Not used.
42
Get other manuals https://www.bkmanuals.com
Setting range (unit)
Specify a
hexadecimal
number.
0 to 2
000 to 3FF
(hexadecimal)
1 to 1000000
(mm/min)