Reporting
Event Description
LOC Mic Activated ECS Alarm
LOC Mic Activated ECS Alarm Restore
LOC/Point ECS # Alarm
LOC/Point ECS # Alarm Restore
Manual pull switch alarm
Manual pull switch alarm restore
Manual pull switch trouble
Manual pull switch trouble restore
Notification output trouble
Notification output trouble restore
Positive Alarm Sequence acknowledge
switch trouble
Positive Alarm Sequence acknowledge
switch trouble restore
SLC LED Module trouble
SLC LED Module trouble restore
Status Point Types Trouble
Status Point Types Trouble Restore
Supervisory Detector Alarm
Supervisory Detector Alarm Restore
Supervisory/Tamper Alarm
Supervisory/Tamper alarm condition restore
Supervisory/Tamper switch trouble
Supervisory/Tamper switch trouble restore
System-based AUX1 switch alarm
System-based AUX1 switch alarm restore
System-based AUX1 switch trouble
System-based AUX1 switch trouble restore
System-based AUX2 switch alarm
System-based AUX2 switch alarm restore
System-based AUX2 switch trouble
System-based AUX2 switch trouble restore
Voice Aux ECS 1 Alarm
Voice Aux ECS 1 Alarm Restore
Voice Aux ECS 2 Alarm
Voice Aux ECS 2 Alarm Restore
Voice Aux ECS 3 Alarm
Voice Aux ECS 3 Alarm Restore
Voice Aux ECS 4 Alarm
148
SIA Reporting Format
SIA pi Modifier
Module
SIA
Parameter
ID #
Event
(If Any)
Code
s
QA
0
QH
0
QA
Emergency #
QH
Emergency #
FA
Zone #
FH
Zone #
FT
Zone #
FJ
Zone #
FT
Group # + 1000
FJ
Group # + 1000
FT
Zone #
FJ
Zone #
ET
0000
ER
0000
UT
0
UJ
0
FS
Zone #
FR
Zone #
FS
Zone #
FR
Zone #
FT
Zone #
FJ
Zone #
UA
1000
UH
1000
UT
1000
UJ
1000
UA
2000
UH
2000
UT
2000
UJ
2000
UA
3
UH
3
UA
4
UH
4
UA
5
UH
5
UA
6
Table 11.2 Report Formats Table (Continued)
Receivers Compatible with the Control Panel
SIA
Fixed Length
Qualifier Event
Format NN -
panel ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
QANN000000
1
QHNN000000
3
QANN0E0000
1
QHNN0E0000
3
FANN000ZZZ
1
FHNN000ZZZ
3
FTNN000ZZZ
1
FJNN000ZZZ
3
FTNN001GGG
1
FJNN001GGG
3
FTNN000ZZZ
1
FJNN000ZZZ
3
ETNN000000
1
ERNN000000
3
UTNN000000
1
UJNN000000
3
FSNN000ZZZ
1
FRNN000ZZZ
3
FSNN000ZZZ
1
FRNN000ZZZ
3
FTNN000ZZZ
1
FJNN000ZZZ
3
UANN001000
1
UHNN001000
3
UTNN001000
1
UJNN001000
3
UANN002000
1
UHNN002000
3
UTNN002000
1
UJNN002000
3
UANN003000
1
UHNN003000
3
UANN004000
1
UHNN004000
3
UANN005000
1
UHNN005000
3
UANN006000
1
IFP-300 Series Manual — P/N LS10145-001SK-E:C 4/6/2022
Contact ID Reporting Format
Group #
Contact #
Code
220
00
000
220
00
000
220 +
00
000
Emergen
cy #
220 +
00
000
Emergen
cy #
115
00
Zone #
115
00
Zone #
373
00
Zone #
373
00
Zone #
320
00
Group #
320
00
Group #
373
00
Zone #
373
00
Zone #
333
00
000
333
00
000
379
00
000
379
00
000
200
00
Zone #
200
00
Zone #
200
00
Zone #
200
00
Zone #
373
00
Zone #
373
00
Zone #
140
01
000
140
01
000
373
01
000
373
01
000
140
02
000
140
02
000
373
02
000
373
02
000
171
00
000
171
00
000
172
00
000
172
00
000
173
00
000
173
00
000
174
00
000

Advertisement